Products

current position:home page>Products>optical instrument>Gentec-EO>

Gentec-EO MAESTRO Touchscreen Display Device

Updated:2025-03-25

Views:44

Product Details

Gentec-EO MAESTRO Touchscreen Display Device Description:

Datasheet(CN) Datasheet(EN) User's Manual PC-Gentec-EO User's Manual Maestro Firmware update procedure

Gentec-EO MAESTRO Touchscreen display device for power & energy measurement. Single-channel, multiple outputs (USB, Ethernet, analog).

HOME

Set device: set all the parameters related to your MAESTRO device.

Set measure: set all the parameters related to your sensor.

Display: set the device in dual or full screen display mode and choose the display(s) you want.

Acquisition: set all your acquisition parameters (time, sample rate, etc.).

Startup config: choose how your MAESTRO will remember your sensor settings at startup.

About: view the main parameters and update your MAESTRO.

SET DEVICE

Use the elements in this menu to set the parameters related to your MAESTRO:

Number of digits: use this menu to set the precision of the measurement.

Serial commands: set compatibility with SOLO2 and use the RS-232, USB and analog outputs

Ethernet: configure the Ethernet communication protocol.

Languages: select the display language: English, German, Japanese or French (firmware V1.04.02 or higher)

SET MEASURE

Use the elements in this menu to set everything related to your measurements:

Wavelength: select one of the standard wavelengths offered, enter a custom value and create your own list of standard wavelengths.

Range: set the measuring range to autoscale or a fixed scale.

Measure mode: use this menu to decide what type of measurements will be displayed: average power, single shot energy, pulse-to-pulse energy, etc.

Corrections: enter multipliers and offsets.

Trigger level: set the trigger level in 0.1% steps, from 0.1% and 99.9%.

DUAL SCREEN DISPLAY

With the dual screen mode, the MAESTRO really takes full advantage of its extra-large screen! Any display mode can be used in both single or dual display mode. In dual display mode, the real time display takes the upper portion of the screen, while any of the other displays (scope, needle, averaging or statistics) is set on the lower portion. The display in the lower portion can be easily changed using the parameters bar with drop-down menus in the center of the screen. You can also expand one of the displays to have it in full screen mode using the maximize button. Just as easily, you can go back to Dual Screen display by using the minimize button.

REAL TIME DISPLAY

This display shows the measured value in real time, with a corresponding bar graph below. The large size of the digits and high contrast of the graphics allow to see the measurement from a good distance. This mode is also always present in dual screen mode, in the upper portion of the screen.

Very large digits

Bar graph

SCOPE DISPLAY

With its line filling from the right of the screen, in a first-in/first-out manner, this display mode is a good approximation of an actual oscilloscope reading. Settings include time (x-axis) and range (y-axis). Basic statistics can also be displayed directly on the screen.

Oscilloscope-type graph

On-screen, real time statistics (min, max and average)

Fully customizable x and y axis

NEEDLE DISPLAY

Exactly like an analog needle, only faster! This mode is particularly useful when tuning a laser. The real time value is also displayed at the top of the screen.

Ultra-fast readings

Great for tuning

Real time value at the top of the screen

Min and max values hold

AVERAGING DISPLAY

This very unique mode is perfect to show the trend of a laser over time. Set the number of points per batch and let the MAESTRO identify the minimum and maximum values of every batch. A yellow curve then follows the average of each batch, displayed as bars on the screen. The wider the difference between the white and blue portions of a bar (corresponding to the min and max values), the more unstable your laser is.

Calculates the min, max and average values of batches of measurements

Perfect to check laser stability over time

Use it with our included PC-Gentec-EO software

Read your measurements directly on your PC thanks to our free proprietary software PC-Gentec-EO. The software supports the following product series: P-LINK, HP, INTEGRA, U-LINK, and MAESTRO.

Practical displays: real-time, scope, needle, averaging, histogram, and statistics

Useful features such as data logging and correction factors

Many statistics available: current value, average value, maximum value, minimum value, RMS stability, PTP stability, repetition rate, average power, and STD deviation

Leverage serial commands

Use our serial commands to communicate directly with the meter without using Gentec-EO's software. You can do so using a terminal emulator software, like PuTTY, or you can just integrate them directly into your own software. All essential functions of the meter are covered by a command. Refer to the user manual of the meter for the list of all commands available.

Build your own software

Suit your unique laser application requirements

Automate your measurements

Key features

Reads ALL Heads

Power: thermopiles, photo detectors and pyroelectrics

Energy: thermopiles (in single shot mode) , photo detectors and pyroelectrics

Large TOUCH SCREEN Color LCD Display

5.6in diagonal

640 x 480 resolution

18bit color

Fully touch screen controls

Multiple Languages Available

Interface fully translated in English, French, German and Japanese

Unique Ergonomic Design

Single or dual graph display

Instant access to the main functions

Function Search tool

USB Key Access

Store data directly on a USB key

Real-Time Statistical Functions

Max, min, average, standard deviation, RMS and PTP stability, pulse # and repetition rate

Available Outputs

USB key, analog output, RS-232, PC-USB, Ethernet

Specifications

Controller and GUI specifications
Interface languages English, German, French and Japanese
Digital display size 112.9 x 84.7 mm LCD - 640 x 480 pixels
Data display Real time, scope, statistics, digital tuning needle and averaging
Analog output 0-1 V, full scale, ±0.5 %
External trigger TTL Compatible, 2-25 V @ 0.4 mA
Serial commands via USB, Ethernet or RS-232 (cable in option)
Data storage via USB key
Battery type 4 x Rechargeable 1.2 V Ni-MH AA
Battery life 6.5 hours
External power supply 9 VDC 1.66 A
Power meter specifications
Power range 4 pW - 30 kW
Digital resolution Digital Resolution PMS
Device accuracy 0.25 % ±5 µV best scale
Statistics Current value, max, min, average, standard deviation, RMS & PTP stability, time
Response time Current value, max, min, average, standard deviation, RMS & PTP stability, time
Energy meter specifications
Energy range 2 fJ to 30 kJ
Digital resolution Digital Resolution EMS
Device accuracy ±1 %
Software trigger level 0.1 to 99.9 %, 0.1 % resolution, default 2 %
Repetition rate 2 000 Hz / 10 000 Hz in sampling
Real-time data transfer 2 000 Hz
Statistics Current value, max, min, average, standard deviation, RMS & PTP stability, pulse #, repetition rate and average power
Physical characteristics
Dimensions 210W x 122H x 45D mm
Weight 0.67 kg

WeChat

Customer Service QQ

Customer Hotline:

010-52867770
0l0-52867771
l3811111452
l7896OO5796

Technical Supports

0l0-52867774
l7896OO5796
info@dorgean.com